top of page
Doors

VEK MNE2

Product Specification 

  • Isolation transformer between loop and detector electronics.

  • Automatic calibration when switching on or changing the adjustment of holding time.

  • Plastic housing with compact size to be mounted directly on DIN-rail (wiring on the housing).

  • Adjustment of unlimited holding time possible.

  • Basic settings easily adjustable with DIP switches. Advanced settings via software.

  • Permanent or pulse output adjustable.

VEK MNE2

Product Information

Dimensions

mm

22.5x79x81 w/o terminals

Housing


Plastic Housing ABS Blue

Power Consumption

mW

500

Power Supply

V AC

10 - 26

Operating Frequency

kHz

30 - 130

Loop Lead-in

m

200

Switching Voltage

V AC

24

Sensitivity Range


0.01 %-0.64 % in 4 steps

Temperature Range

ËšC

-37 / +70

Type of Connection


Colour coded plugin terminals